
Baseboard Management Controller (BMC)
4 Move the shorting block from pins
1 |
|
|
|
| 2 - 3 | Default - Boot block | |
| 2 |
| 3 | ||||
J1B1 |
|
|
| 3 |
| protected | |
|
|
|
| ||||
|
|
|
|
| 1 - 2 | Boot block unprotected | |
1 | 2 |
| |||||
|
|
|
|
|
|
|
|
5 Follow the instructions in “Closing the server case” on page 72, then reconnect the power cord.
6 Download the current SUP CD image from www.support.gateway.com and create a
7
8
Follow the instructions in “Booting from the SUP CD:” on page 43.
Follow the instructions on the menu to update the firmware.
At the completion of the firmware update, an error message 009 will
Important | be displayed. This error message can be ignored. |
|
9 Turn off the server, then disconnect the power cord and wait for the Standby power LED to turn off.
10
11 Replace the processor air baffle by following the instructions in “Removing and installing the processor air baffle” on page 67.
www.gateway.com | 49 |