Parameter Description

Initial Billing Interval: Specifies the length of the first billing interval (in seconds). For example, if your provider charges a fixed $X for the first 5 minutes enter 300.

Note: Set the timer to 0 disables it. The Billing

Interval timer is also, effectively disabled.

Default: 60 seconds.

Billing Interval: Specifies the increments your Service Provider uses to bill subsequent usage of your ISDN line (usage after the initial Billing Interval expires). For example if your Provider charges $Y per minute for each minute following the Initial Billing Interval, enter 60.

Note: Setting the timer to 0 disables it. The

Initial Billing Interval remains in effect.

Default: 60 seconds.

1st B-channel Delay before opening: Specify the amount of time (in seconds) the throughput on your D- channel must exceed the Opening Threshold before the 1st B-channel is added to the AO/DI connection.

For example, if you specify 5 seconds, and the Opening Threshold is 70%, once the throughput on the D-channel reaches 70%, there will be a delay of 5 seconds before the 1st B-channel is added to the AO/DI connection. If the throughput drops below 70% during the 5 seconds, the 1st B-channel will not be added to the connection.

Opening Threshold: Specify the threshold (percentage) that the throughput on your D- channel must exceed before the 1st B-channel is added to the AO/DI connection.

Closing Threshold: Specify the threshold (percentage) that the throughput on your B- channel must be below before the 1st B-channel is dropped from the AO/DI connection.

Note: This option is only available with AO/DI support.

DIVA T/A ISDN Modem User’s Guide 45

Page 45
Image 45
Hayes Microcomputer Products DIVA T/A ISDN manual Parameter Description