DIVA T/A ISDN Modem User’s Guide 46
Parameter Description
2nd B-
channel Delay before opening: Specify the amount of
time (in seconds) the throughput on your 1st B-
channel must exceed the Opening Threshold
before the 2nd B-channel is added to the AO/DI
connection.
For example, if you specify 5 seconds, and the
Opening Threshold is 70%, once the throughput
on the 1st B-channel reaches 70%, there will be
a delay of 5 seconds before the 2nd B-channel is
added to the AO/DI connection. If the
throughput drops below 70% during the 5
seconds, the 2nd B-channel will not be added to
the connection.
Opening Threshold: Specify the threshold
(percentage) that the throughput on your 1st B-
channel must exceed before the 2nd B-channel is
added to the AO/DI connection.
Closing Threshold: Specify the threshold
(percentage) that the throughput on your 2nd B-
channel connection must be below before the
2nd B-channel is dropped from the AO/DI
connection.
Note: This option is available without AO/DI
support. If you have BACP configured, you can
configure this option to specify when the 2nd B-
channel will be added to the connection as the
traffic volume warrants.