2Installation

2.1Pre-installation Information

If the controller has not been removed from its shipping carton, inspect the carton for damage then remove the controller.

Inspect the unit for any obvious shipping damage and report any damage due to transit to the carrier.

Make sure a bag containing mounting hardware is included in the carton with the controller.

Check that the model number shown on the inside of the case agrees with what you have ordered.

2.2Model Number Interpretation

Write your controller’s model number in the spaces provided below and circle the corresponding items in each table. This information will also be useful when you wire your controller.

Instructions

Select the desired key number. The arrow to the right marks the selection available.

Make the desired selections from Tables I through VI using the column below the

proper arrow.

A dot ( ) denotes availability.

Key Number

 

I

 

II

 

III

 

IV

V

_ _ _ _ _ _

-

_ _

-

_ _ _ _

-

_ _ _

-

_ _ _ _ _

-

_ _

VI

_

KEY NUMBER - UDC3200 Single Loop Controller

Description

Digital Controller for use with 90 to 264Vac Power Digital Controller for use with 24Vac/dc Power

Selection Availability

DC3200

DC3201

TABLE I - Specify Control Output and/or Alarms

 

Current Output (4 to 20ma, 0 to 20 ma)

 

Electro Mechanical Relay (5 Amp Form C)

Output #1

Solid State Relay (1 Amp)

 

Open Collector transistor output

 

Dual 2 Amp Relays (Both are Form A) (Heat/Cool Applications)

 

No Additional Outputs or Alarms

Output #2 and Alarm

One Alarm Relay Only

#1 or Alarms 1 and 2

E-M Relay (5 Amp Form C) Plus Alarm 1 (5 Amp Form C Relay)

 

Solid State Relay (1 Amp) Plus Alarm 1 (5 Amp Form C Relay)

 

Open Collector Plus Alarm 1 (5 Amp Form C Relay)

TABLE II - Communications and Software Selections

 

None

Communications

Auxiliary Output/Digital Inputs (1 Aux and 1 DI or 2 DI)

RS-485 Modbus Plus Auxiliary Output/Digital Inputs

 

 

10 Base-T Ethernet (Modbus RTU) Plus Auxiliary Output/Digital Inputs

 

Standard Functions, Includes Accutune

Software Selections

Math Option

 

Set Point Programming (1 Program, 12 Segments)

 

Set Point Programming Plus Math

Reserved

No Selection

Infrared interface

Infrared Interface Included (Can be used with a Pocket PC)

TABLE III - Input 1 can be changed in the field using external resistors

 

TC, RTD, mV, 0-5V, 1-5V

Input 1

TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA

TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, 0-10V

 

 

Carbon, Oxygen or Dewpoint (Requires Input 2)

 

None

Input 2

TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA

TC, RTD, mV, 0-5V, 1-5V, 0-20mA, 4-20mA, 0-10V

 

 

Slidewire Input (Requires two Relay Outputs)

C_

E _ A _ T _ R _ _ 0 _ B _ E _ A _ T

0 _ _ _

1 _ _ _

2 _ _ _

3 _ _ _

_ 0 _ _ _ A _ _ _ B _ _ _ C _ _

_ _ 0 _

_ _ _ R

1 _ _

2 _ _

3 _ _

1 6 0

_ 00 _ 10 _ 20 _ 40

04/08

UDC3200 Universal Digital Controller Operator Manual

5

Page 11
Image 11
Honeywell UDC3200 manual Pre-installation Information, Model Number Interpretation