Output Algorithm

 

 

Output 1/2

 

 

Function of

 

 

Function of Other Outputs

 

Type

 

 

Option

 

 

Output 1/2

 

 

Output #3

 

Output #4

 

Auxiliary Output

Time Simplex

Single Relay

 

Output 1

 

Alarm 2

 

Alarm 1

 

Not Needed

 

 

 

Current Output

 

INU

 

Output 1

 

Alarm 1

 

Not Needed

 

 

 

Dual Relay

 

Output 1

 

Alarm 2

 

Alarm 1

 

Not Needed

Time Duplex or

Single Relay

 

Output 1

 

Output 2

 

Alarm 1

 

Not Needed

TPSC or Position

Current Output

 

INU

 

Output 2

 

Output 1

 

Not Needed

Proportional

 

 

 

 

 

 

 

 

 

 

 

 

Dual Relay

 

Outputs 1 and

 

Alarm 2

 

Alarm 1

 

Not Needed

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

Current Simplex

Single Relay

 

INU

 

Alarm 2

 

Alarm 1

 

Output 1

 

 

 

Current Output

 

Output 1

 

Alarm 2

 

Alarm 1

 

Not Needed

 

 

 

Dual Relay

 

INU

 

Alarm 2

 

Alarm 1

 

Output 1

Current Dup. 100%

Single Relay

 

INU

 

Alarm 2

 

Alarm 1

 

Outputs 1 and 2

Current = COOL

Current Output

 

Outputs 1 and

 

Alarm 2

 

Alarm 1

 

Not Needed

and HEAT

 

 

 

2

 

 

 

 

 

 

 

 

 

 

Dual Relay

 

INU

 

Alarm 2

 

Alarm 1

 

Outputs 1 and 2

Current Duplex

Single Relay

 

N/A

 

N/A

 

N/A

 

N/A

50%

 

Current Output

 

Output 1

 

Alarm 2

 

Alarm 1

 

Output 2

Current = HEAT

 

 

 

 

 

 

 

 

 

 

 

 

Dual Relay

 

N/A

 

N/A

 

N/A

 

N/A

Aux Out = COOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current/Time

Single Relay *

 

Output 1

 

Output 2

 

Alarm 1

 

Output 2

Current = COOL

Current Output

 

Output 2

 

Output 2

 

Alarm 1

 

Not Needed

Time = HEAT

Dual Relay *

 

Outputs 1 & 2

 

Alarm 2

 

Alarm 1

 

Output 2

Time/Current

Single Relay *

 

Output 1

 

Output 2

 

Alarm 1

 

Output 1

Time = COOL

Current Output

 

Output 1

 

Output 2

 

Alarm 1

 

Not Needed

Current = HEAT

Dual Relay *

 

Outputs 1 & 2

 

Alarm 2

 

Alarm 1

 

Output 1

TPSC = Three Position Step Control

N/A = Not Available – This output algorithm type cannot be performed with this Output 1/2 option.

INU = Installed, Not Used – The installed Output 1/2 option is not used for the configured output algorithm type.

Not Needed = Auxiliary Output is Not Needed to provide the desired output algorithm and can be used for another purpose. With the proper configuration, Auxiliary Output could also be used as a substitute for the Current Output.

*To obtain this output algorithm type with these Output 1/2 Options: 1) Configure the OUTALG selection as “TIME D”; 2) Configure Auxiliary Output for “OUTPUT” and; 3) Scale the Auxiliary Output as necessary for the desired output algorithm type. For these selections, the Output 1 (HEAT) and Output 2 (COOL) signals will be present both on the Auxiliary Output and on the two relays normally used for Time Duplex.

04/08