Computer powered off automatically and the Power LED flashes Red two times, once every second, followed by a two second pause, and the computer beeps two times. (Beeps stop after fifth iteration but LEDs continue flashing).

Cause

Solution

 

 

 

Processor thermal protection activated:

1.

Ensure that the computer air vents are not blocked and

A fan may be blocked or not turning.

 

the processor cooling fan is running.

2.

Open hood, press power button, and see if the

OR

 

processor fan spins. If the processor fan is not spinning,

The heat sink is not properly attached to the processor.

 

make sure the fan's cable is plugged onto the system

 

board header.

 

3.

If fan is plugged in, but is not spinning, then replace the

 

 

heat sink/fan assembly.

 

 

 

System does not power on and the LEDs on the front of the computer are not flashing.

Cause

Solution

System unable to power on.

Press and hold the power button for less than 4 seconds. If the hard drive LED turns green, then:

1.Check that the voltage selector, located on the rear of the power supply on some models, is set to the appropriate voltage. Proper voltage setting depends on your region.

2.Replace the system board.

OR

Press and hold the power button for less than 4 seconds. If the hard drive LED does not turn on green then:

1.Check that the unit is plugged into a working AC outlet.

2.Open computer and check that the power button board cable is properly connected to the system board.

3.Check that power supply cables are properly connected to the system board.

4.Check to see if the 5V_aux light on the system board is turned on. If it is turned on, then replace the power button board.

5.If the 5V_aux light on the system board is off, then replace the power supply.

6.Replace the system board.