Communications Checks

Table 7-30

 

Communications Checks

 

 

 

 

 

Checks

Action

 

 

 

Is your computer configured to the

These parameters are required to

parameters described in the

communicate with the printer. Verify your

configuration instructions?

computer’s communications port

 

 

 

configuration matches these parameters.

 

 

 

Note: If these parameters are not set

 

 

 

properly, they may yield a 40, 20, or

 

 

 

22 ERROR on the printer’s Control Panel.

 

 

 

For Serial Communications only

 

 

 

 

Does the printer’s baud rate match that

Run the printer’s Self Test to verify the

of the computer’s communications port?

baud rate setting. At the computer, verify

 

 

 

that the baud rate is set correctly in any

 

 

 

configuration files.

 

 

 

Note: A baud rate problem may cause a

 

 

 

40 ERROR.

 

 

 

Are you using the correct cable for

See the cable wiring in Chapter 3.

communications between the computer

 

and the printer?

 

 

Hint: On an RS-232 cable, pins 2 and 3

 

 

 

may need to be reversed at the

 

 

 

printer-end of the cable.

 

 

 

Are you using the correct RS-232-C

During the communications “handshake,”

protocol?

 

 

the printer transmits both the XON/XOFF

 

 

 

signal, and the DTR signal. The DTR

 

 

 

(Data Terminal Ready) signal may be

 

 

 

either negative going, or positive going.

 

 

 

DTR polarity is set at the printer’s Control

 

 

 

Panel. The XON may be set to normal

 

 

 

(only transmitted when data is needed),

 

 

 

or Robust XON (transmitted every

 

 

 

second). This feature is configurable from

 

 

 

the Control Panel. DTR is available at pin

 

 

 

20, and XOFF is transmitted from pin 2

 

 

 

of the printer.

 

 

 

 

7-54 Troubleshooting

Page 284
Image 284