Replacing the High Voltage Contact

Assembly/Feed Guide Assembly

The Toner Cartridge Guide Plate and the High Voltage Contact Assembly/Feed Guide Assembly must be installed together. Allow plenty of time to perform this procedure because several iterations of the process may be necessary.

1 Set the contact assembly over its mounting holes.

2 Slide the Toner Cartridge Guide Plate into position on a diagonal line (see Figure 6-57).

3 Working the two parts together, lift the rear of the HVCP to provide enough clearance to install the Guide Plate.

4 When the Guide Plate is in position, press it into place on the sheet metal.

5 Press the HVCP into its mounting slots.

6 Install the Laser Shutter Pivot Pin and test the Laser Shutter for free operation.

7 Replace the gear cover (see Figure 6-56).

Figure 6-57 Orientation of HVCP and Left Guide Plate