Thermistor Removal

Figure 1-47 Thermistor Connector

1 Remove the Wire Harness Cover as shown in Figure 6-47.

2 Remove the (2) screws from the thermoswitch connector (see Figure 6-47, callout 1).

3 Release the thermoswitch latch from the paper sensor flag side of the Fuser Assembly (behind the side cover, see Figure 6-47, callout 2).

4 Slide the thermoswitch to the gear side of the fuser and release it from the fuser frame (callout 3).

N o t e

When installing the thermoswitch, make sure the

 

sensing surface contacts the fusing roller

 

uniformly. If it does not, straighten the leaf

 

spring.

(continued on next page)