HP 4 C2001A, C2021A, 5 C3916A Voltage Test Points, Measuring the DC Voltage Levels, TB 201Voltages

Models: 4 plus C2037A 5m C3917A C2021A 5n C3952A 4 C2001A 5 C3916A

1 453
Download 453 pages 32.37 Kb
Page 299
Image 299

Voltage Test Points

The operating voltages of the printer can be verified by:

1 Listening for the exhaust fan. A rotating fan indicates that the +5 VDC and +24A VDC voltages are present. (The fan runs on +24A VDC. The +5 VDC enables the +24A VDC.)

2 Listen for the Main Motor. If the Main Motor runs, the +24B VDC is enabled, therefore +24A VDC must be present.

Measuring the DC Voltage Levels

The DC voltage levels can be measured directly on the DC Controller TB 201. TB 201 connects the DC Controller with the Power Supply. (See the Main Wiring Diagram, and Figure 7-16 or 7-17, the DC Controller PCA Layout in the previous section.) Remove the Formatter cage to access the DC Controller. The voltages on TB201 are as follows:

Table 7-39

TB 201Voltages

 

 

 

 

 

Voltage

 

Color

Pin Number

 

 

 

 

+5 VDC

 

Brown

1, 2

 

 

 

 

+24 VDC

 

Red

3

 

 

 

 

Ground

 

Blue

4, 5, 6

 

 

 

 

 

 

 

 

 

 

 

 

Figure 7-21 TB 201 Voltages

Troubleshooting 7-69

Page 299
Image 299
HP 4 C2001A, C2021A, 5n C3952A manual Voltage Test Points, Measuring the DC Voltage Levels, TB 201Voltages, Color Pin Number