6 Tests and Error Messages

MaxiLife Test Sequence and Error Messages

Run-Time Errors

During the normal usage of the PC Workstation (and at boot), MaxiLife continually monitors vital system parameters. These include: temperature errors, fan malfunctions, power voltage drops, board PLL problems and CPU problems.

If both the fan for disks and the I/O slot are not connected (both are runtime error 1), only the “Fan disk” will be displayed.

Test

Error Code

Action to Take

 

 

 

During normal usage of the PC, HP MaxiLife

FAN CPU

Rear fan, system board,1 fan cable.

continually checks vital system parameters. If an

 

 

FAN PCI

PCI fan, PCI cards, system board, fan cable.

error occurs, a message appears on the LCD

 

 

panel.

TEMP. CPU

Rear fan, airflow guide, “Airflow Separator”2, system board.

 

TEMP PCI

PCI fan, airflow guide, “Airflow Separator”, system board, PCI

 

 

cards.

 

 

 

 

TEMP DISK

Rear fan, airflow guide, “Airflow Separator”, disk temperature,

 

 

sensor, system board.

 

 

 

 

POWER ERRORS

Power supply unit, VRM, system board.

 

 

 

 

BOARD PLL

Processor(s), system board

 

 

 

 

POWER 12V ERROR

Power supply unit has failed. Try the following:

 

 

1 Replace the power supply unit with a known working one

 

VCC CPU 1 ERROR

 

2 If the problem persists, replace the system board

 

 

 

VCC CPU 2 ERROR

 

 

 

 

 

 

POWER 1.5V ERROR

 

 

 

 

 

POWER 1.8V ERROR

 

 

 

 

 

POWER 2.5V ERROR

 

 

 

 

 

POWER 3.3V ERROR

 

 

 

 

 

POWER 5V ERROR

 

 

 

 

1.Special cases: Board PLL = System board needs replacing. CPU error = Reset or power off the system to recover.

2.A retaining bar holds the airflow guide in place, dividing inside the chassis into two separate areas (processor and PCI slots) for better cooling.