Failure Detection Pair configuration

Command: /cfg/ufd/fdp

[FDP Menu]

 

ltm

- Link to Monitor Menu

ltd

- Link to Disable Menu

ena

- Enable FDP

dis

- Disable FDP

current

- Display current FDP configuration

Use these commands to configure a Failure Detection Pair, which consists of one Link to Monitor (LtM) and one Link to Disable (LtD). When the switch detects a failure on the LtM, it automatically disables the ports in the LtD.

The following table describes the Failure Detection Pair (FDP) configuration Menu options.

Table 178 Failure Detection Pair Configuration Menu options

Command

Description

 

 

ltm

Displays the Links to Monitor menu.

 

 

ltd

Displays the Links to Disable menu.

 

 

ena

Enables the FDP Parameters.

 

 

dis

Disables the FDP Parameters.

 

 

current

Displays the current FDP configuration.

 

 

Link to Monitor configuration

Command: /cfg/ufd/fdp/ltm

[Failure Link

to Monitor Menu]

addport

- Add port to Link to Monitor

remport

- Remove port from Link to Monitor

addtrnk

- Add trunk to Link to Monitor

remtrnk

- Remove trunk from Link to Monitor

cur

- Display current LtM configuration

The following table describes the Link to Monitor (LtM) Menu options. The LtM can consist of only one uplink port (ports 20-24) or a single trunk containing only uplink ports.

Table 179 Link to Monitor Menu options

Command

Description

 

 

addport <port number>

Adds a port to the LtM. Only uplink ports (20-24) are allowed in the LtM.

 

 

remport <port number>

Removes a port from the LtM.

 

 

addtrnk <1-12>

Adds a trunk group to the LtM. The LtM trunk group can contain only uplink ports

 

(20-24).

 

 

remtrnk <1-12>

Removes a trunk group from the LtM.

 

 

cur

Displays the current LtM configuration.

 

 

Configuration Menu 157

Page 157
Image 157
HP xw460c Blade manual Failure Detection Pair configuration, Link to Monitor configuration, Addport port number