Boot Options Menu

Introduction

You must be logged in to the switch as the administrator to use the Boot Options Menu.

The Boot Options Menu provides options for:

Selecting a switch software image to be used when the switch is next reset.

Selecting a configuration block to be used when the switch is next reset.

Downloading or uploading a new software image to the switch via FTP/TFTP.

Menu information

Command: /boot

[Boot Options

Menu]

 

image

- Select software

image to use on next boot

conf

- Select config block to use on next boot

mode

- Select CLI mode

to use on next boot

prompt

- Prompt for selectable boot mode

gtimg

- Download new software image via FTP/TFTP

ptimg

- Upload selected

software image via FTP/TFTP

reset

- Reset switch [WARNING: Restarts Spanning Tree]

cur

- Display current

boot options

 

 

 

Each of the Boot Options Menu commands is discussed in greater detail in the following sections.

Updating the switch software image

The switch software image is the executable code running on the switch. A version of the image ships with the switch, and comes pre-installed on the device. As new versions of the image are released, you can upgrade the software running on the switch.

Upgrading the software image on the switch requires the following:

Loading the new image onto a FTP/TFTP server on your network

Downloading the new image from the FTP/TFTP server to the switch

Selecting the new software image to be loaded into switch memory the next time the switch is reset

Downloading new software to the switch

The switch can store up to two different software images, called image1 and image2, as well as boot software, called boot. When you download new software, you must specify where it should be placed: either into image1, image2, or boot.

For example, if your active image is currently loaded into image1, you would probably load the new image software into image2. This lets you test the new software and reload the original active image (stored in image1), if needed.

To download new software to the switch, you will need the following:

The image or boot software loaded on a FTP or TFTP server on your network

The hostname or IP address of the FTP or TFTP server

The user name and password for FTP server, if necessary

The name of the new software image or boot file

NOTE: The DNS parameters must be configured if specifying hostnames. See the “Domain name system configuration” section in the “Configuration Menu” chapter.