SECTION 11—BATTERIES

3.Remove the fuse holder from left side of charger next to battery charger cable and perform one of the following:

If fuse is bad, replace with new 250V, 4 amp fuse.

If fuse is good, replace charger. Refer to Replacing the On-Board Battery Charger on page 109.

4.Connect joystick and turn power On. Refer to Disconnecting/Connecting the Joystick on page 123.

5.Perform one of the following:

If wheelchair functions, install top shroud. Refer to Removing/Installing the Top Shroud on page 87.

If wheelchair does not function, replace charger. Refer to Replacing the On-Board Battery Charger on page 109.

Charger

Battery Charger Cable

Fuse Holder with 250V,

4 amp Fuse

FIGURE 11.6 Replacing the On-Board Battery Charger Fuse

Replacing the On-Board Battery Charger

WARNING

DO NOT replace the battery charger fuse with anything other than a 250V 4 Amp fuse. Otherwise, equipment damage and/or personnel injury may occur.

DO NOT attempt to remove the battery charger with power applied to the wheelchair. Otherwise, equipment damage and/or personnel injury may occur.

NOTE: For this procedure, refer to FIGURE 11.7 on page 111.

NOTE: Take note of position and orientation of battery charger cables and tie-wraps for reinstallation.

NOTE: The output of the battery charger is fused with a 250V, 4 amp fuse. The fuse holder is located at the left side of the charger as it is mounted to the wheelchair. This fuse should be checked

Part No. 1125075

109

Pronto® Series

Page 109
Image 109
Invacare M51, M50, M61 service manual Replacing the On-Board Battery Charger Fuse