Image 24

SECTION 3—SAFETY INSPECTION/TROUBLESHOOTING

NUMBER OF FLASHES

DIAGNOSTICS CODE

ERROR CODE DESCRIPTION

SUB CODE*

DETAILS OF ERROR CODE

POSSIBLE SOLUTION

 

 

 

 

 

 

5

E05

Left Park Brake

00

Left Park Brake Drive-Time

Check the left park brake connections and

 

 

Fault

 

Test Failed

cable.

 

 

 

 

 

 

 

 

 

01

Left Park Brake Output

 

 

 

 

 

Enabled When Wheelchair

 

 

 

 

 

Idle

 

 

 

 

 

 

 

 

 

 

02

Left Park Brake Output Did

 

 

 

 

 

not Enable When Entering

 

 

 

 

 

Drive Mode

 

 

 

 

 

 

 

 

 

 

03

Left Park Brake fault during

 

 

 

 

 

power-up testing

 

 

 

 

 

 

 

 

 

 

04

Left park brake feedback low

 

 

 

 

 

during drive (park brake

 

 

 

 

 

short)

 

 

 

 

 

 

 

6

E06

Right Park Brake

00

Right Park Brake Drive-Time

Check the right park brake connections

 

 

Fault

 

Test Failed

and cable.

 

 

 

 

 

 

 

 

 

01

Right Park Brake Output

 

 

 

 

 

Enabled When Wheelchair

 

 

 

 

 

Idle

 

 

 

 

 

 

 

 

 

 

02

Right Park Brake Output Did

 

 

 

 

 

not Enable When Entering

 

 

 

 

 

Drive Mode

 

 

 

 

 

 

 

 

 

 

03

Right Park Brake fault during

 

 

 

 

 

power-up testing

 

 

 

 

 

 

 

 

 

 

04

Right park brake feedback

 

 

 

 

 

low during drive (park brake

 

 

 

 

 

short)

 

 

 

 

 

 

 

7

E07

Remote Fault

00

Local SR Fault (CPU,

Check the communications bus, connec-

 

 

 

 

EEPROM, etc.)

tions and wiring. Replace the remote.

 

 

 

 

 

 

 

 

 

01

Joystick fault at the remote

 

 

 

 

 

 

 

 

 

 

02

Speed pot fault at the remote

 

 

 

 

 

 

 