SECTION 10—SHROUDS AND FRAME

Side

Shroud

Inner Walking

Shroud Beam

Small Screw

Large

Mounting

Small

Hole

Large ScrewMounting

Hole

FIGURE 10.4 Removing/Installing the Inner Shrouds

Removing/Installing the Pivot Tube

NOTE: For this procedure, refer to FIGURE 10.5 on page 92.

Removing

1.Remove the front headtube assembly. Refer to Removing/Installing the Front Headtube Assembly on page 83.

2.Remove the side shroud. Refer to Removing/Installing the Side Shrouds on page 88.

3.remove the locknut, two small washers and large washer securing the rear of the pivot tube to the threaded post.

4.Remove the pivot tube from the frame.

NOTE: The front and rear bushings may fall out of the pivot tube when it is removed. Retain these for installation.

Part No. 1125075