Juniper Networks J2320 manual J4350 and J6350 Cooling System

Models: J2320

1 330
Download 330 pages 32.01 Kb
Page 60
Image 60

J2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Power supplies on J6350 Services Routers are hot-removable and hot-insertable. You can remove and replace a redundant power supply without powering down the router or disrupting the routing functions. To avoid electrical injury, carefully follow the instructions in “Replacing Power System Components” on page 193.

NOTE: You cannot mix DC and AC power supplies in the same chassis.

WARNING: DC-powered Services Routers are intended for installation only in a restricted access location.

J4350 and J6350 Cooling System

The cooling system includes three fans at the rear of the chassis. The airflow produced by these fans keeps router components within the acceptable temperature range (see Figure 21 on page 39). The speed of the fans is adjusted automatically according to the current temperature.

An air filter protects the air intake opening at the front of the chassis and must be replaced periodically. For instructions, see “Replacing Air Filters on J4350 and J6350 Routers” on page 208.

The Routing Engine monitors the temperature of the router components. If the maximum temperature specification, as measured at the CPU junction, is exceeded and the router cannot be adequately cooled, the Routing Engine shuts down the hardware components.

When the CPU temperature reaches 80°C (176°F), a yellow alarm is triggered. When the CPU temperature reaches 105°C (221°F), the system shuts down. There is no red alarm for temperature. You can view the CPU junction temperature using the show chassis routing-enginecommand. The CPU temperature runs a few degrees higher than the routing engine temperature displayed on the Monitor>Chassis page of the J-Web interface.

NOTE: On J4350 and J6350 routers that are not designed to comply with Network Equipment Building System (NEBS) criteria, the temperature at which the system shuts down is 90°C (194°F) rather than 105°C (221°F). To verify that the system is a NEBS-compliant system, run the show chassis hardware command. A NEBS-compliant system displays the term NEBS in the output.

An additional fan is part of each power supply. This fan is not regulated by the operating system.

38J4350 and J6350 Services Router Hardware Features

Page 60
Image 60
Juniper Networks J2320 manual J4350 and J6350 Cooling System, 38 J4350 and J6350 Services Router Hardware Features