Chapter 10: Replacing Hardware Components

Figure 76: Location of J2320 and J2350 Internal Compact Flash

To replace the internal compact flash:

1.Place an electrostatic bag or antistatic mat on a flat, stable surface.

2.Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to the ESD point on the chassis, or to an outside ESD point if the router is disconnected from earth ground. For more information about ESD, see “Preventing Electrostatic Discharge Damage” on page 249.

3.Press and release the power button to power off the router. Wait for the POWER LED to turn off.

4.Remove the power cable from the power source receptacle.

5.Remove chassis cover. (See “Removing and Replacing the Chassis Cover on J2320 and J2350 Routers” on page 178.)

WARNING: If the fans are still rotating, wait until they stop before proceeding with the next step.

6.With a Phillips screwdriver, loosen the pan head screws that secure the internal compact flash slot cover.

7.Remove the compact flash slot cover.

8.Gently grasp the compact flash, and slide it out of the compact flash slot (see Figure 77 on page 182).