MX240 Ethernet Services Router Hardware Guide

Total RLDRAM

256

MB

Total DDR DRAM

4096

MB

Start time:

 

2007-12-06 11:33:01 PST

Uptime:

 

4 hours, 34 minutes, 48 seconds

Slot 2 information:

 

 

State

 

Online

Temperature

33

degrees C / 91 degrees F

Total CPU DRAM

1024

MB

Total RLDRAM

256

MB

Total DDR DRAM

4096

MB

Start time:

 

2007-12-06 11:33:05 PST

Uptime:

 

4 hours, 34 minutes, 44 seconds

For further description of the output from the commands, see the JUNOS System

Basics and Services Command Reference.

If a DPC is not functioning normally, follow these guidelines to troubleshoot the DPC:

Make sure the DPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight.

Troubleshooting the Power System

To verify that a power supply is functioning normally, perform the following steps:

Check the LEDs on each power supply faceplate.

If an AC power supply is correctly installed and functioning normally, the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit. For more information about the LEDs, see “AC Power Supply LEDs” on page 22.

If a DC power supply is correctly installed and functioning normally, the PWR OK, BRKR ON, and INPUT OK LEDs light green steadily. For more information about the LEDs, see “DC Power Supply LEDs” on page 24.

Issue the CLI show chassis environment pem command to check the status of installed power supplies. As shown in the sample output, the value Online in the rows labeled State indicates that the power supplies in slots 0 and 1 are functioning normally:

user@host> show chassis environment pem

PEM 0 status:

 

State

Online

Temperature

OK

DC output

OK

PEM 2 status:

 

State

Online

84Troubleshooting the Power System

Page 112
Image 112