MX240 Ethernet Services Router Hardware Guide

Connecting the Alarm Relay Wires

To connect the alarm relay wires between a router and an alarm-reporting device (see Figure 38 on page 91):

1.Prepare the required length of replacement wire with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm2).

2.Insert the replacement wires into the slots in the front of the block. Use a 2.5-mm flat-blade screwdriver to tighten the screws and secure the wire.

3.Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.

4.Attach the other end of the wires to the external device.

Replacing Cooling System Components

Replacing the Fan Tray on page 92

Replacing the Air Filter on page 94

Replacing the Fan Tray

The router has one fan tray that installs vertically in the rear of the chassis. The fan tray contains three fans. The fan tray is hot-removable and hot-insertable.

The fan tray is located in the rear of the chassis on the right side. The fan tray weighs about 4.2 lb (1.9 kg).

NOTE: To prevent overheating, install the replacement fan tray immediately after removing the existing fan tray.

To replace the fan tray, use the following procedures:

Removing the Fan Tray on page 92

Installing the Fan Tray on page 93

Removing the Fan Tray

To remove the fan tray (see Figure 39 on page 93):

1.Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see “Preventing Electrostatic Discharge Damage” on page 130.

2.Loosen the captive screws on the fan tray faceplate.

3.Grasp the fan tray handle and pull it out approximately 1 to 3 inches.

92Replacing Cooling System Components

Page 120
Image 120
Juniper Networks MX240 manual Replacing Cooling System Components, Replacing the Fan Tray, Connecting the Alarm Relay Wires