Chapter 13: Replacing Hardware Components

Figure 58: Connecting Power Cables to the DC Power Supply

4.Replace the clear plastic cover over the terminal studs on the faceplate.

5.Verify that the DC power cable is connected correctly, that it does not touch or block access to router components, and that it does not drape where people could trip on it.

6.Attach the power cable to the DC power source.

7.Turn on the dedicated facility circuit breaker to the power supply.

8.Verify that the INPUT OK LED on the power supply is lit green steadily.

9.Switch the circuit breaker on the power supply to the ON position and observe the status LEDs on the power supply faceplate. If the power supply is correctly installed and functioning normally, the PWR OK, BRKR ON, and INPUT OK LEDs light green steadily.

Replacing the Cable Management System

Removing the Cable Management System on page 121

Installing the Cable Management System on page 122

Removing the Cable Management System

The cable management system is located on both sides of the DPC card cage. The cable management system weighs approximately 0.3 lb (0.14 kg).

To remove the cable management system (see Figure 59 on page 122):

1.Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see “Preventing Electrostatic Discharge Damage” on page 130.