MX240 Ethernet Services Router Hardware Guide

SCB LEDs on page 20

Fan LEDs on page 20

Alarm Relay Contacts on page 21

Figure 13: Front Panel of the Craft Interface

NOTE: At least one SCB must be installed in the router for the craft interface to obtain power.

Alarm LEDs and Alarm Cutoff/Lamp Test Button

Two large alarm LEDs are located at the upper right of the craft interface (see Figure 13 on page 18). The circular red LED lights to indicate a critical condition that can result in a system shutdown. The triangular yellow LED lights to indicate a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously.

A condition that causes an LED to light also activates the corresponding alarm relay contact on the craft interface, as described in “Alarm Relay Contacts” on page 21.

To deactivate red and yellow alarms, press the button labeled ACO/LT (for “alarm cutoff/lamp test”), which is located to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and deactivates the device attached to the corresponding alarm relay contact on the craft interface.

Table 11 on page 19 describes the alarm LEDs and alarm cutoff button in more detail.