HDMI Enhance
For setting the color range of HDMI signals. When connecting to a PC monitor, set this to “On”.
This item is selectable only when [HDMI/SDI Out] is set to “HDMI” or “HDMI+SDI”.
[Setting Values: On, ROff]
SD Aspect
For setting the style of displaying downconverted images on a 4:3 aspect ratio screen.
Side Cut:
Displays image with the left and right sides cut off.
Letter:
Displays as a wide image with the top and bottom blackened.
Squeeze:
Displays image that is squeezed horizontally. [Setting Values: Side Cut, Letter, RSqueeze]
Memo :
When [Record
this item appears as “” and cannot be selected. ( P111 [ System ] )
SD Set Up
For selecting whether to add a setup signal to the video signal output from the [AV] output terminal. Setup signals are added when “7.5%” is selected. [Setting Values: 7.5%, 0.0%]
(Default values: 7.5% (U model), fixed at “0.0%” (E model))
Memo :
Depending on the menu settings of the camera recorder and the condition of the cable connected to it, the setup signal setting may be fixed at “0.0%”. “0.0%” is displayed in gray in this case.
Audio Set Item
Input1 Mic Ref.
For setting the reference input level when the [INPUT1] selection switch is set to “MIC” or “MIC +48V”.
[Setting Values: 62dB, 56dB, R50dB, 44dB, 38dB]
Input2 Mic Ref.
For setting the reference input level when the [INPUT2] selection switch is set to “MIC” or “MIC +48V”.
[Setting Values: 62dB, 56dB, R50dB, 44dB, 38dB]
Int. Mic Gain
For setting the sensitivity of the builtin microphone. [Setting Values: +12dB, +6dB, R0dB]
AUX Gain
For setting the sensitivity of the [AUX] terminal input.
[Setting Values: +12dB, +6dB, R0dB]
Ref. Level
For setting the audio reference level to be recorded to the SD card. (Applies to both [CH1/CH2].) [Setting Values: 12dB, 18dB, R20dB]
Limiter
For setting the limiter operation. Ref. Level:
Sets “Ref. Level” to the maximum recording level.
8dBFS, 5dBFS:
Sets “8dBFS” or “5dBFS” to the maximum recording level.
Off:
Depending on the settings of the [CH1/CH2 AUTO/MANUAL] selection switches, the operation may be different as described below. The limiter does not function when
“MANUAL” is set.
The limiter functions at 5 dBFS when “AUTO” is set.
[Setting Values: Ref. Level, 8dBFS, R5dBFS, Off]
AGC Response
Attack Time
Sets the time to activate the limiter. [Setting Values: Fast, RMiddle, Slow]
Decay Time
Sets the time to deactivate the limiter operation. [Setting Values: Fast, RMiddle, Slow]