AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-23
General Link Properties Configuration
General link properties are configurable using menus accessed directly from the link
configuration menu. The following configuration items are available:

Auto Disable Error Limit

Description
This menu item disables a link when the rate of errors received on that link exceeds a
user-specified threshold. This prevents a bad link or cable from streaming enough
errors to lock up or crash AI296.
Menu Item Type
Data
Link Type Availability
Async, AsyncPPP, HDLC-Bridge, MLT, SyncPPP, and X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.
2. For Auto Disable Error Limit, enter the associated item number, a comma, and the
error limit value. (For example, 9,25000.) The default is 0.
zAuto Disable Error Limit zLink Type
zFlow Control zPassive Link with Clocking
zHardware Interface (Interface Type) zPort Data Bits
zInterface Mode zPort Parity
zLink Description zPort Speed
zLink Mode zPort Stop Bits
zLink Number zSync Port Encoding
zLink State zXon Repeat Interval