AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-34
This example displays Passive Link with Clocking set to Enabled.
\
Port Data Bits
Description
This menu item defines the number of databits in a data byte.
Menu Item Type
Toggle
Link Type Availability
Async and AsyncPPP
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.
2. For 06*Port Data Bits, enter 6 to select 7 or 8. The default is 8.
This example displays 06*Port Data Bits set to 7.
Configuration in the AI296 Local Menu System
1. Access the Async Link Menu or AsyncPPP Link Menu.
2. For Port data bits, select Seven or Eight. The default is Eight.
Quick X.25 Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 05
Interface Mode . . . . . . . . . . . . . . . . . . . . . . . DTE [DCE]
Port speed (0=external clocking) . . . . . . . . . . . . . . . . . . . . 9600
X25 Passive Link Mode . . . . . . . . . . . [Normal] Passive Extended
Passive Link with Clocking . . . . . . . . . . . . . [Enabled] Disabled
>6
Menu 4.2.11.12
01 Link Number (1-16)--------------------------------------------------------01
02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)---------------- Async
03 Link Description------------------------------ Async link 1
04*Link state (Enabled, Disabled)-------------------------------------- Enabled
05+Port speed------------------------------------------------------------- 9600
06*Port Data Bits (7, 8)------------------------------------------------------7