AI296 Version 9.8x User’s Guide

Link Configuration: X.25 Parameters Configuration

Link Type Availability

X.25

Configuration in the AI198 Menu System

1.Access menu 4.2.11.12.8.

2.For 13 R20 restart count, enter 13, and the counter value. The default is 1.

3.For 14 R22 reset transmission count, enter 14, and the counter value. The default is 1.

4. For 15 R23 clear retransmission count, enter 15, and the counter value. The default is 1.

5.For 16 R28 registration retransmission count, enter 16, and the counter value. The

default is 1.

This example displays:

z13 R20 restart count set to 150

z14 R22 reset transmission count set to 25

z 15 R23 clear retransmission count set to 34

z16 R28 registration retransmission count set to 52.

>16,52

 

 

 

 

 

Menu 4.2.11.12.8

01*X25

Facilities negotiation-----------------------------------------------

OFF

02*Max

packet size (128, 256, 512)------------------------------------------

128

03

Packet window size (1-7)-------------------------------------------------

002

04

X121 local address (0-15 decimal digits)------------------------------------

05

T20

restart timer (0-3200000ms)--------------------------------------

1750000

06

T21

call timer (0-3200000ms)-----------------------------------------

1000000

07

T22

reset timer (0-3200000ms)----------------------------------------

0020000

08

T23

clear timer (0-3200000ms)----------------------------------------

0180000

09

T24

window timer (0-3200000ms)---------------------------------------

2356000

10

T25

data retransmission timer (0-3200000ms)--------------------------

1650000

11

T26

interrupt timer (0-3200000ms)------------------------------------

2300000

12

T28

registration timer (0-3200000ms)---------------------------------

0090000

13

R20

restart count (0 - 255)----------------------------------------------

150

14

R22

reset transmission count (0 - 255)-----------------------------------

025

15

R23

clear retransmission count (0 - 255)--------------------------------

034

16

R28

registration retransmission count (0 - 255)--------------------------

052

 

 

 

 

Configuration in the AI296 Local Menu System

1.Access the X.25 Link Menu.

2.Select X.25 Parameters Menu. The X.25 Parameters Menu appears.

3.For R20 restart count, enter the counter value. The default is 1.

4.For R22 reset transmission count, enter the counter value. The default is 1.

5. For R23 clear retransmission count, enter the counter value. The default is 1.

6-79

Page 173
Image 173
Kentrox AI296 manual Default is This example displays