AI296 Version 9.8x User’s Guide

Link Configuration: X.25 Parameters Configuration

Menu Item Type

Data

Link Type Availability

X.25

Configuration in the AI198 Menu System

1.Access Menu 4.2.11.12.8.

2.For 05 T20 restart timer, enter 5, and the timer value. The default is 180000.

3.For 06 T21 call timer, enter 6, and the timer value. The default is 200000.

4.For 07 T22 reset timer, enter 7, and the timer value. The default is 10000.

5.For 08 T23 clear timer, enter 8, and the timer value. The default is 180000.

6.For 09 T24 window timer, enter 9, and the timer value. The default is 75000.

7.For 10 T25 data retransmission timer, enter 10, and the timer value. The default is

150000.

8.For 11 T26 interrupt timer, enter 11, and the timer value. The default is 180000.

9.For 12 T28 registration timer, enter 12, and the timer value. The default is 180000. This example displays:

z05 T20 restart timer set to 1750000

z06 T21 call timer set to 1000000

z07 T22 reset timer set to 20000

z08 T23 clear timer set to 180000

z09 T24 window timer set to 2356000

z10 T25 data retransmission timer set to 1650000

z11 T26 interrupt timer set to 2300000

z12 T28 registration timer set to 90000.

>12,90000

 

 

 

 

Menu 4.2.11.12.8

01*X25

Facilities negotiation-----------------------------------------------

OFF

02*Max

packet size (128, 256, 512)------------------------------------------

128

03

Packet window size (1-7)-------------------------------------------------

002

04

X121 local address (0-15 decimal digits)------------------------------------

05

T20

restart timer (0-3200000ms)--------------------------------------

1750000

06

T21

call timer (0-3200000ms)-----------------------------------------

1000000

07

T22

reset timer (0-3200000ms)----------------------------------------

0020000

08

T23

clear timer (0-3200000ms)----------------------------------------

0180000

09

T24

window timer (0-3200000ms)---------------------------------------

2356000

10

T25

data retransmission timer (0-3200000ms)--------------------------

1650000

11

T26

interrupt timer (0-3200000ms)------------------------------------

2300000

12

T28

registration timer (0-3200000ms)---------------------------------

0090000

 

 

 

 

6-82

Page 176
Image 176
Kentrox AI296 manual 12,90000