AI296 Version 9.8x User’s Guide
AI296 Commands: link
9-59
link
Description
This command is used to:
zForce a serial link to connect or disconnect
Note: When this command is used to disconnect a serial link, all calls are torn
down. The serial link does not come back online until command link
start is issued.
Important: If you are connected to the AI296 shell using a serial port, remember
not to disable that port or else loss of connectivity will result.
zRestart a link, which is a stop followed by a start
zShow a configuration summary for a link or range of links.
Command Types
shell and winslc
Formats
For the shell command:
link {
link_range
| * } { restart | start | stop }
For the winslc command:
winslc
baseport
link {
link_range
| * } { start | stop | restart }
Parameters
*Specifies all links.
baseport
Defines the baseport number for AI296.
link_range
Defines a link or range of links. Valid values are 1 to 32. Individual
values are separated by commas (,) and hyphens (-). For example,
1,4-6 specifies links 1, 4, 5, and 6.
Note: This parameter applies to any action the user is trying
perform (start, stop, restart, or show information).
restart Restarts the serial links.
start Enables the serial links.
stop Disables the serial links.