AI296 Version 9.8x User’s Guide
Link Configuration: LAPB Parameters Configuration
6-50
This example displays:
z05 T1 ack timer set to 19000
z06 T2 ack delay timer set to 20000
z07 T4 idle timer set to 50000.
Configuration in the AI296 Local Menu System
1. Access the MLT or X.25 Link Menu.
2. Select LAPB Menu or X.25 LAPB Menu. The MLT LAPB Menu or X.25 LAPB Menu
appears.
3. For T1 Ack Timer, enter the timer value. The default is 3000.
4. For T2 Ack Delay Timer, enter the timer value. The default is 4000.
5. For T4 Idle Timer, enter the timer value. The default is 25000.
This example displays:
zT1 Ack Timer set to 19000
zT2 Ack Delay Timer set to 20000
zT4 Idle Timer set to 50000.
N2 Retry Counter
Description
This menu item defines the maximum number of accepted retransmissions for
unacknowledged frames.
>7,50000
Menu 4.2.11.12.8
01*Interface mode (DTE or DCE)----------------------------------------------DCE
02*Frame level disconnect (Active, Passive, Other)---------------------- Active
03 Frame Window size (1 - 7)--------------------------------------------------7
04 N2 retry count (0 - 255)-------------------------------------------------150
05 T1 ack timer (100 - 25500 ms)------------------------------------------19000
06 T2 ack delay timer (100 - 25500 ms)------------------------------------20000
07 T4 idle timer (0 - 200000 ms)-----------------------------------------050000
MLT LAPB Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03
Frame Level Disconnect . . . . . . . . . . . [Active] Passive Other
Frame Window Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
N2 Retry Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
T1 Ack Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19000
T2 Ack Delay Timer . . . . . . . . . . . . . . . . . . . . . . . . . . .20000
T4 Idle Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50000