AI296 Version 9.8x User’s Guide

Link Configuration: General Link Properties Configuration

Passive Link with Clocking

Description

This menu item enables or disables an X.25 passive link from supplying a clock value while the link is in the inactive state.



Note: Old AT&T 5ESS interface cards (TN983) require clocking with the passive link set up.

Menu Item Type

Toggle

Link Type Availability

X.25

Configuration in the AI198 Menu System

1.Access Menu 4.2.11.12.

2.For 13*Passive Link with Clocking, enter 13 to select Enabled or Disabled. The

default is Disabled.

This example displays 13*Passive Link with Clocking set to Enabled.

>13

 

 

Menu 4.2.11.12

01 Link number (1-16)--------------------------------------------------------

05

02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)----------------

X.25

03 Link Description------------------------------

X.25 link 5

04*Link state (Enabled, Disabled)--------------------------------------

Disabled

05*Link mode (Normal, Passive, Extended)-------------------------------

Normal

06 Port speed (0 - 128000 bps, 0 is external clocking)-------------------

009600

07+X25 LAPB Parameters

 

08+X25 Parameters

 

09+Virtual Circuits

 

10*Hardware Interface (RS232,RS530,V.35)----------------------------------

RS232

11+BX25 Configuration

 

12 Auto Disable Error Limit (0-1000000)---------------------------------

0000000

13*Passive Link with Clocking (Enabled, Disabled)----------------------

Enabled

 

 

Configuration in the AI296 Local Menu System

1.Access the X.25 Link Menu.

2.From the X.25 Link Menu, select Quick X.25 Menu. The Quick X.25 Menu appears.

3.For Passive Link with Clocking, select Enabled or Disabled. The default is Disabled.

6-33