AI296 Version 9.8x User’s Guide

AI296 Commands: staeia

staeia

Description

This command displays the status of the EIA leads.

Command Types

shell and winslc

Formats

For the shell command:

staeia { link_range * }

For the winslc command:

winslc baseport staeia { link_range * }

Parameters

link_range Defines a link or range of links. Valid values are 1 to 32. Individual values are separated by commas (,) and hyphens (-). For example, 1,4-6specifies links 1, 4, 5, and 6.

*Specifies all links.

baseport Defines the baseport of AI296.

Examples

This example displays the status of the EIA leads for links 1 to 5.

[296]staeia 1-5

 

 

 

 

Link Type

Status

 

IN

OUT

 

 

 

DCD

CTS

DTR

RTS

1: ASY

Enabled

-

-

+

+

2: X25

Enabled

-

-

+

+

3: X25

Enabled

-

-

+

+

4: X25

Enabled

-

-

+

+

5:X25 Disabled

[296]

Column

Description

 

 

DCD

DCD is an incoming EIA lead control signal. The plus symbol (+)

 

indicates that this lead is asserted. The minus symbol (-) indicates that

 

the lead is negated.

 

 

9-89