AI296 Version 9.8x User’s Guide
AI296 Commands: diag-info
9-38
Examples
This example displays the WAN Diag Info screen, which is accessed by typing W.
This example displays diagnostic information for STREAMS allocation and memory,
which are accessed by typing M.
W A N D I A G I N F O
LINK STATE TX_PEND RX_WANT NO_BUF BYTE_IN BYTE_OUT
1 30 0 1 0 0 759050
2 0 0 1 0 0 0
3 0 0 1 0 0 0
4 0 0 1 0 0 0
5 0 0 1 0 0 0
6 0 0 1 0 0 0
7 0 0 1 0 0 0
8 0 0 1 0 0 0
9 0 0 1 0 0 0
10 0 0 1 0 0 0
11 0 0 1 0 0 0
12 0 0 1 0 0 0
13 0 0 1 0 0 0
14 0 0 1 0 0 0
15 0 0 1 0 0 0
16 0 0 1 0 0 0
Enter W-an, M-emory, A-sync, E-thernet, T-cp or Q-uit:
Column Description
LINK Displays the link number.
STATE Displays the state of the WAN driver. Two states are available:
z0 means the X.25 frame level is not established.
z30 means the X.25 frame level is established.
TX_PEND Displays the state of the transaction if one is pending for transmission.
RX_WANT Displays the state of the buffer if another buffer is needed.
NO_BUF Displays the number of times the receiver cannot be started because no
buffers were available.
BYTE_IN Displays the count of the number of bytes coming in.
BYTE_OUT Displays the count of the number of bytes going out.