AI296 Version 9.8x User’s Guide

Link Configuration: X.25 Parameters Configuration

Configuration in the AI296 Local Menu System

1.Access the X.25 Link Menu.

2.Select X.25 Parameters Menu. The X.25 Parameters Menu appears.

3.For Protocol Version, select 1980, 1984, or 1988. The default is 1984.

This example displays Protocol Version set to 1988.

 

X.25 Parameters Menu

 

 

 

Link being configured

. . . . . . .

. 03

X25

Facilities Negotiation

Enabled

[Disabled]

Max Packet Size

[128]

256

512

Packet Window Size

. . . . .

. .

. . . .2

X121 Local Address

. . . ................

 

T20

Restart Timer

. . . . .

. .

.1750000

T21

Call Timer

. . . . .

. .

.1000000

T22

Reset Timer

. . . . .

. .

.. 20000

T23

Clear Timer

. . . . .

. .

. 180000

T24

Window Timer

. . . . .

. .

.2356000

T25

Data Retransmission Timer

. . . . .

. .

.1650000

T26

Interrupt Timer

. . . . .

. .

.2300000

T28

Registration Timer

. . . . .

. .

.. 90000

R20

Restart Counter

. . . . .

. .

. . .150

R22

Reset Transmission Counter

. . . . .

. .

. . . 25

R23

Clear Transmission Counter

. . . . .

. .

. . . 34

R28

Registration Transmission Counter

. . . . .

. .

. . . 52

Protocol Version

1980

1984

[1988]

 

 

 

 

 

X.25 Counter Settings

Description

The X.25 counter settings are configured using four menu items:

zR20 restart counter—Defines the maximum number of times a reset can be sent without receiving reset confirmation.

zR22 reset transmission counter—Defines the maximum number of times a reset can be sent without receiving clear confirmation.

zR23 clear transmission counter—Defines the maximum number of times a clear request can be sent without clearing confirmation.

zR28 registration transmission counter—Defines the maximum number of times a

registration request can be sent without receiving registration confirmation.

Menu Item Type

Data

6-78

Page 172
Image 172
Kentrox AI296 manual Counter Settings