AI296 Version 9.8x User’s Guide

Link Configuration: X.25 Parameters Configuration

This example displays Max Packet Size set to 256.

 

 

X.25 Parameters Menu

 

 

Link being configured . . .

. . . . . . . . . . . . . . . . . . .

. . .

03

X25

Facilities Negotiation

. . . . . . . . . . . . . Enabled

[Disabled]

Max

Packet Size

. . . . . . . . . . . . . . 128

[256]

512

 

 

 

 

 

Packet Window Size

Description

This menu item defines the packet window size, which specifies the number of packets that can be sent before receiving confirmation that the first packet was received correctly.

Menu Item Type

Data

Link Type Availability

X.25

Configuration in the AI198 Menu System

1.Access Menu 4.2.11.12.8.

2.For 03 Packet window size, enter 3, and the window size. The default is 2.



Note: To access the menu on a Soneplex NE, set Packet window size to 1.

This example displays 03 Packet window size set to 006.

>3,6

 

 

Menu 4.2.11.12.8

01*X25 Facilities negotiation-----------------------------------------------

ON

02*Max packet size (128, 256, 512)------------------------------------------

512

03 Packet window size (1-7)-------------------------------------------------

006

 

 

Configuration in the AI296 Local Menu System

1.Access the X.25 Link Menu.

2.Select X.25 Parameters Menu. The X.25 Parameters Menu appears.

3.For Packet Window Size, enter the value. The default is 2.



Note: To access the menu on a Soneplex NE, set Packet window size to 1.

6-76