AI296 Version 9.8x User’s Guide

Link Configuration: General Link Properties Configuration

zV.35—Data transmission standard for a trunk interface between a network access device and a packet network.

Menu Item Type

Toggle

Link Type Availability

Async, AsyncPPP, HDLC-Bridge, MLT, SyncPPP, and X.25

Configuration in the AI198 Menu System

1.Access Menu 4.2.11.12.

2.For Hardware Interface, enter the associated item number to select RS232, RS530, or V.35. The default is RS232.

This asynchronous link example displays 15*Hardware Interface set to V.35.

>15

 

 

Menu 4.2.11.12

01 Link Number (1-16)--------------------------------------------------------

01

02*Link Type (Async, X25, HDLC, SyncPPP, AsyncPPP, MLT)----------------

Async

03 Link Description------------------------------

Async link 1

04*Link state (Enabled, Disabled)--------------------------------------

Enabled

05+Port speed-------------------------------------------------------------

9600

06*Port Data Bits (7, 8)------------------------------------------------------

8

07*Port Stop Bits (1, 2)------------------------------------------------------

1

08*Port Parity (None, Odd, Even)-------------------------------------------

None

09*Flow Control (None, XonXoff)-----------------------------------------

None

10 Xon Repeat interval (0 - 120s with 0 = no repeat)------------------------

000

11+Connect Options

 

12+Disconnect Options

 

13+RTS/DTR Lead Control Options

 

14+Modem Options

 

15*Hardware Interface (RS232,RS530,V.35)-----------------------------------

V.35

 

 

Configuration in the AI296 Local Menu System

1.Access the Link Menu.

2.For Interface Type, select RS-232,RS-530, or V.35.

This example displays Interface Type set to V.35.

 

 

Async Link Menu

 

 

 

Link to configure

. . . . . . .

. . . . . . . . .

. . . . .

. . . . . .

. . 2

Link state . . .

. . . . . . . .

. . . . . . . . .

. . . . .

. Up

[Down]

Link Type . .

[Async] X.25

HDLC-Bridge

SyncPPP

AsyncPPP

MLT

Interface Type .

. . . . . . . . . . . . . . . .

RS-232

RS-530

[V.35]

6-26

Page 120
Image 120
Kentrox AI296 manual Async, AsyncPPP, HDLC-Bridge, MLT, SyncPPP, This example displays Interface Type set to