AI296 Version 9.8x User’s Guide

Link Configuration: Virtual Circuit Configuration

The timer type, range, and default settings depend on the PVC type. Refer to Table 6-2 for PVC types, timer types, ranges, and defaults.

Table 6-2 PVC and Timer Type

PVC Type

Timer Type

Range

Default

Active

Call Timer

30 to 600 s

30 s

Connect on Activity

Inactivity Timer

1 to 600 s

1 s

Passive

Reset Timer

0 s

0 s

This example displays:

 

 

 

z

Low PVC set to 30

 

 

 

z

High PVC set to 50

 

 

 

z

PVC Type set to Active

 

 

z

Timer Value set to 230.

 

 

 

 

PVC Edit Menu

 

Link being configured .

. . . . . . . .

. . . . . . . . . .

. . . . . . . 03

Low PVC

. . . . . . . .

. . . . . . . . . .

. . . . . . . .. 30

High PVC

. . . . . . . .

. . . . . . . . . .

. . . . . . . .. 50

PVC Type

. . . . . .

Passive [Active]

ConnectOnActivity

Timer Value

. . . . . . . .

. . . . . . . . . .

. . . . . . . . 230

SVC Configuration Settings

Description

SVCs are network connections that are established when transmission is required and are disconnected when the session is complete. The SVC settings are configured using the following menu items:

zIncoming only SVC low—Defines the minimum LCN used for incoming only SVCs.

zIncoming only SVC high—Defines the maximum LCN used for incoming only SVCs.

zTwo-way SVC low—Defines the minimum LCN used for an SVC.

zTwo-way SVC high—Defines the maximum LCN used for an SVC.

zOutgoing only SVC low—Defines the minimum LCN used for outgoing only SVCs. AI296 can place calls on outgoing only SVCs greater than the maximum PVC and/or two-way SVC.

zOutgoing only SVC high—Defines the maximum LCN used for outgoing only SVCs. AI296 can place calls on outgoing only SVCs.