AI296 Version 9.8x User’s Guide

System Configuration: TID to Modem Mux Configuration

This example displays Init String set to conn23.

 

TID To Modem Mux Edit Menu

 

 

TID to route

. . . . . . . . . . . . . . .....................

 

Port Data Bits

. . . . . . . . . . . . . . .

Seven

[Eight]

Port Stop Bits

. . . . . . . . . . . . . . . . .

[One]

Two

Port Parity

. . . . . . . . . . . . . [None]

Even

Odd

Init String

. . . . . . . . . ........................

conn23

 

 

 

 

Port Bit Settings

Description

There are three menu items available for configuring TID to Modem Mux port bits:

zPort Data Bits—Defines the number of databits in a data byte.

zPort Stop Bits—Defines the number of stop bits for TID to Modem Mux. A stop bit is an extra bit at the end of an asynchronous character that helps the receiver recognize the end of the character.

zPort Parity—Defines parity, which is a process for detecting whether or not bits of data have been altered during data transmission.

Menu Item Types

Toggle for all menu items

Configuration in the AI198 Menu System

1.Access Menu 4.2.14-2.6.

2.From Menu 4.2.14-2.6, enter a value from 2 to 11. Menu 4.2.14-2.6.1 appears.

3.For 02*Port Data Bits, enter 2, to select 7 or 8. The default is 8.

4.For 03*Port Stop Bits, enter 3, to select 1 or 2. The default is 1.

5.For 04*Port Parity, enter 4, to select None, Even, or Odd. The default is None. This example displays:

z02*Port Data Bits set to 7

z03*Port Stop Bits set to 1

z04*Port Parity set to Even.

>4,Even

 

 

 

 

Menu 4.2.14-2.6.1

01 TID to route--------------------------------------------

 

02*Port Data Bits (7,

8)------------------------------------------------------

7

03*Port Stop Bits (1,

2)------------------------------------------------------

1

04*Port Parity (None,

Even, Odd)-------------------------------------------

Even

 

 

 

4-30