AI296 Version 9.8x User’s Guide

Link Configuration: Virtual Circuit Configuration

Table 6-1 PVC and Timer Type (Continued)

PVC Type

Timer Type

Range

Default

 

 

 

 

Passive

Reset Timer

0 s

0 s

 

 

 

 

This example displays:

z01*PVC Type set to Connect

z02 LCN Low set to 5

z03 LCN High set to 15

z04 INACTIVITY Timer Interval set to 240.

>4,240

 

 

 

 

 

Menu 4.2.11.12.9.2.1

01*PVC

Type (Passive, Active, Connect on activity)

----------------------Connect

02

LCN

Low (* for all LCNs for the link)-----------------------------------

0005

03

LCN

High----------------------------------------------------------------

0015

04

INACTIVITY Timer Interval (seconds)------------------------------------

00240

 

 

 

 

Configuration in the AI296 Local Menu System

1.Access the X.25 Link Menu.

2.Select Quick X.25 Menu. The Quick X.25 Menu appears.

3.For Number of PVCs, enter the number of PVCs to be configured. The default is 0.

4.For SVC Low, enter a minimum SVC value that is higher than the number of PVCs. Valid values are from 0 to 4095. The default is 1.

5.For SVC High, enter a maximum SVC value that is higher than the minimum SVC value. Valid values are from 0 to 4095. The default is 1.

6.Save your work.

7.From the Quick X.25 Menu, select PVC Menu. The PVC Summary Menu appears.

8.For Edit PVC, enter the number of the PVC to be edited. This value must be in the range of configured PVCs. The PVC Edit Menu appears.

9.For Low PVC, enter the minimum PVC value.

10.For High PVC, enter the maximum PVC value.

11.For PVC Type, select Passive, Active, or ConnectOnActivity. The default is Passive.

12.For Timer Value, select the timer interval value.

6-89