AI296 Version 9.8x User’s Guide

Link Configuration: Quick X.25 Configuration

Link Type Availability

X.25

Configuration in the AI296 Local Menu System

1.Access the X.25 Link Menu.

2.Select Quick X.25 Menu. The Quick X.25 Menu appears.

3.For X25 Passive Link Mode, select Normal, Passive, or Extended. The default is Normal.

4.For Passive Link with Clocking, select Enabled or Disabled. The default is Disabled.

This example displays X25 Passive Link Mode set to Passive and Passive Link with

Clocking set to Enabled.

 

 

 

Quick X.25 Menu

 

Link being configured

. . . . . . . . . . . . . . . . .

. . . 02

Interface Mode

DTE [DCE]

Port speed (0=external clocking)

. . . . . . . . . . . . . . . . .

. . . 9600

X25 Passive Link Mode

. . . . . Normal [Passive]

Extended

Passive Link with Clocking . . .

. . . . . . . . . . [Enabled]

Disabled

Port Speed

Description

This menu item defines how many bits of data AI296 can transmit per second over a link.



Note: There is an aggregate baud rate limitation of 359 kilobits per second for link groups 1 to 4, 5 to 8, 9 to 12, and 13 to 16. For example, the total baud rate configured for links 1 to 4 must not exceed 359 kilobits per second. If it does, then the AI296 disables the links and reports an error.

Menu Item Type

Data

Link Type Availability

X.25

Configuration in the AI296 Local Menu System

1.Access the X.25 Link Menu.

2.Select Quick X.25 Menu. The Quick X.25 Menu appears.

6-67

Page 161
Image 161
Kentrox AI296 manual Normal Passive Extended