AI296 Version 9.8x User’s Guide
AI296 Commands: trace
9-112
trace
Description
This command configures which X.25 rejected call codes (cause and diagnostic)
appear on the log port. This command can also be used to see the current trace level.
The default trace level is 3.
Command Types
shell and winslc
Formats
For the AI296 system command:
trace
level
For the winslc command:
winslc
baseport
trace
level
Parameters
Note: If you enter this command without a level, the current trace level number
appears.
Table 9-3 shows the priority assigned to each trace level.
baseport
Defines the baseport number for AI296.
level
Defines the minimum trace level on the log port. For example, if
level
is set to 2, all X.25 events assigned a priority of 2 or higher will appear
on the log port. The valid range for this argument is 1 to 5. The default
level is 3.
Table 9-3 Trace Priority Levels
Priority Level
X25_TRACE 1
X25_NORMAL 2
X25_MINOR 3 (default)
X25_MAJOR 4
X25_FATAL 5