A-2
AI296 Version 9.8x User’s Guide
AI296 System Codes: X.25 Cause Codes and Diagnostic Codes
X.25 Cause Codes and Diagnostic Codes
X.25 cause codes indicate events that triggered X.25 packets. Possible values for the
cause codes can vary depending on the type of packet (CLEAR REQUEST,
REGISTRATION CONFIRMATION, RESET REQUEST, or RESTART).
X.25 diagnostic codes provide additional tips about the nature of a specific problem.
Unlike cause codes, diagnostic codes do not vary depending on the type of packet.
Note: Diagnostic codes can be produced by any equipment that handles virtual
circuits and can propagate through all equipment that handles virtual circuits.
Because of this, diagnostic codes may not indicate a problem with AI296.
The following X.25 cause codes and diagnostic codes are available:
zStandard Reset Indication Cause Codes
zKentrox-Specific Reset Indication Cause Codes
zStandard Clear Indication Cause Codes
zStandard ISO Diagnostic Codes
zCCITT Diagnostic Codes
zKentrox-Specific Diagnostic Codes

Standard Reset Indication Cause Codes

Reset indication cause codes apply to reset packets. Table A-1 lists the standard
reset indication cause codes (in hexadecimal format) and their meanings.
Table A-1 Standard Reset Indication Cause Codes
Cause Code Description
0x00 Remote DTE originated reset
0x01 Reset out of order
0X03 Reset due to remote procedure error
0X05 Reset due to local procedure error
0X07 Reset due to network congestion
0X09 Reset due to remote DTE operational
0X0F Reset due to network operational
0X11 Reset due to incompatible destination