AI296 Version 9.8x User’s Guide

 

Link Configuration: Disconnect Options Configuration

 

This example displays Disconnect when DCD is off set to On and Disconnect when a Break

character is received set to Off for an async link.

 

 

Disconnect Options Menu

 

 

Link being configured

. .

4

Disconnect when DCD is off

[On]

Off

Disconnect when a Break character is received

On

[Off]

Disconnect String

Description

This menu item configures the string the link sends before the link disconnects. The following character values apply:

z<b> sends a break signal.

z<n> represents the decimal value of an ASCII character. Valid values are 0 to 255.

ztext represents the text value in the string.

z<p #> represents a pause control sequence. # is the number of tenths of seconds to pause. Valid values are 1 to 20 (for 0.1 seconds to 2 seconds).

For example, string <b>login<13><p 10><b> sends:

zA break signal

zThe text “login”

zA carriage return

zA one second pause

zAnother break signal.

Menu Item Type

Data

Link Type Availability

Async

Configuration in the AI198 Menu System

1.Access Menu 4.2.11.12.12.

2.For 07 Disconnect string, enter 7, and the disconnect string. Maximum length is 80 characters.

6-21