The Driver Manager

The Query Format is set to encode the projector response, as defined in Table 15:

Table 15: Projector Query Response (Power)

The projector response is: 20H 85H 01H xxH 10H DATA01 ... DATA16

The projector status of operation appears in DATA06:

DATA06:

00H

04H

05H

06H

 

Idling

Power On

Cooling

Idling (error

 

 

 

 

occurrence)

An actual response could be:

20H 85H 01H 00H 10H 00H 01H 00H 00H 00H 04H FFH FFH FFH FFH

4. In the Query Format tab, set the query format, see Figure 166:

Figure 166: Query Format Window (Power)

5.In the Query Command Details tab, fill in the look up table (the Expected Result Table in the Query Command Details tab).

The lookup table lets you match a command string (from the projector protocol) to a projector state1 and assign a status that will appear in Site-CTRL and the Web pages.

The example in Figure 167 shows, for example, that the command 0x04 matches the On state and that means that the status is OK; the command 0x06 matches an Error state and the Error status is assigned and will appear in Site-CTRL and the Web pages.

1 On and STBY states are built-in and you can add other states as required (for example, Cooling, Error and so on)