The Driver Manager

Table 13 shows the query format details:

Table 13: Lamp Hour Query Format Details

Feature

Function

Lamp Hour Example

Begin

Set the byte from which the response starts

The lamp hour data starts with the byte in

 

 

position 5, that is, the first four characters

 

 

are ignored

Terminated

END_OF_RES: the data ends with the final character in the packet

By Length: the response will always include

 

BY_CHAR: a certain character will define the end of the response

four bytes (a fixed length)

 

(for example, “A”)

 

 

BY_LENGTH: the response will always have a set number of

 

 

characters

 

Stop Value

The stop value will be defined according to the type of termination

Four bytes only

 

selected:

 

 

For END_OF_RES: N/A

 

 

For BY_CHAR: the character that defines the end of the response

 

 

For BY_LENGTH: the number of fixed characters that comprise

 

 

the response

 

Answer Format:

BINARY_HEX, ASCII, ASCII_Base_16 or BIT

BINARY_HEX

Endian Type/

Endian Type: select little or big, to define the response reading

Little Endian: the response starts from the

Bit Num

direction

byte with lowest value to the largest

 

BIT number: when selecting the BIT answer format, set the BIT

 

 

number

 

Response Units:

HOURS, MINUTES, SECONDS, USE_LOOK_UP_TABLE (relevant

SECONDS: the lamp hours will appear in

 

to the power query, see Section 9.2.2), or NONE (an arbitrary

seconds

 

number without units, not relevant to lamp hours)

 

4.In the Alerts tab, check Alert Enabled, to let the room controller continuously monitor the lamp hours.

5.In the Alerts tab, set the alert values, see Figure 164.

You can find the Max Lamp Hour value in the projector’s manual.

The warning and critical values are set according to the control room requirements. In this example, the projector maximum lamp hours are 3000 hours.

Figure 164: Alerts Window (Lamp Hours)

77