Kyocera FS-1010 service manual Interlock switch

Models: FS-1010

1 172
Download 172 pages 36.88 Kb
Page 80
Image 80

Interlock switch

The interlock switch is located on the high voltage board and opened and closed in conjunction with the front cover or the top cover via the interlock lever. This switch connects and disconnects the +24 V DC power supply line. If the front cover or the top cover is open, the interlock switch is open, and the +24 V DC to the high voltage output circuit, bias board, engine board, and the power supply board is disconnected, deactivating the high voltage output, laser output, main motor output for safety. The cooling fan is an exception: Since the cooling fan is directly fed with +24 V DC from the power supply unit at the primary side (+24V1) of the interlock switch, the cooling fan is not deactivated even the cover is open.

Top cover

Projection

Interlock lever

Projection

Engine board,

Bias board,

etc.

Power supply unit

 

 

 

High voltage

Interlock

 

output circuit

Triac, etc.

switch

 

 

 

 

+24V2

 

+24 V DC

 

 

+24V1

output

 

 

 

High voltage board

 

 

 

 

 

 

 

 

Cooling fan

 

Front cover

Machine left side view

Figure 4-3-11 Interlock switch

FS-1010

4-29

Page 80
Image 80
Kyocera FS-1010 service manual Interlock switch