5-2-9 Removing the laser scanner unit and the eraser lamp

1.Remove the process unit (See page 5-4).

2.Remove the top cover/face-down output tray, right cover, and the left cover (See pages 5-5 and 5-6).

3.Remove four connectors 1.

4.Remove five screws 2 and four screws 3.

5.While keeping the ground joint plate 4 away from the LSU plate 5, remove the LSU plate.

4

3

2

5

21

Figure 5-2-28 Removing the LSU plate

FS-1010

5-29

Page 109
Image 109
Kyocera FS-1010 service manual Removing the laser scanner unit and the eraser lamp, Removing the LSU plate