Table 15. EasyLED panel LEDs (continued)

LED

Description

Action

OVER SPEC

The power supplies are

If the 12V channel C error LED is lit, complete

(Continued)

using more power than

the following steps:

 

their maximum rating.

1.

Turn the server off and disconnect the

 

 

 

 

 

power from the server.

 

 

2.

Remove the SAS/SATA RAID riser card,

 

 

 

DIMMs in connectors 1 through 8, and the

 

 

 

microprocessor in socket 1.

 

 

 

Note: The server will not power-on when

 

 

 

the microprocessor in socket 1 is not

 

 

 

installed in the server. You will need to

 

 

 

toggle the switch block (SW3) to pin 6 to

 

 

 

power-on the server.

 

 

3.

Restart the server to see if the problem

 

 

 

remains.

 

 

4.

Reinstall each device that was removed in

 

 

 

step b one at a time, starting the server

 

 

 

each time, to isolate the failing device.

 

 

5.

Replace any failing device.

 

 

6.

(Trained service technician only) Replace

 

 

 

the system board, if the problem remains.

If the 12V channel D error LED is lit, complete the following steps:

1.Turn the server off and disconnect the power from the server.

2.Remove the microprocessor in socket 1. Note: The server will not power-on when the microprocessor in socket 1 is not installed in the server. You will need to toggle the switch block (SW3) to pin 6 to power-on the server.

3.Restart the server to see if the problem remains.

4.Reinstall the microprocessor in socket 1 and restart the server.

5.Replace any failing device.

6.(Trained service technician only) Replace the system board, if the problem remains.

(Continued on the next page.)

Chapter 7. Solving problems 145

Page 161
Image 161
Lenovo 3797 manual Led