Table 15. EasyLED panel LEDs (continued)
LED | Description | Action | |
OVER SPEC | The power supplies are | If the 12V channel C error LED is lit, complete | |
(Continued) | using more power than | the following steps: | |
| their maximum rating. | 1. | Turn the server off and disconnect the |
|
| ||
|
|
| power from the server. |
|
| 2. | Remove the SAS/SATA RAID riser card, |
|
|
| DIMMs in connectors 1 through 8, and the |
|
|
| microprocessor in socket 1. |
|
|
| Note: The server will not |
|
|
| the microprocessor in socket 1 is not |
|
|
| installed in the server. You will need to |
|
|
| toggle the switch block (SW3) to pin 6 to |
|
|
| |
|
| 3. | Restart the server to see if the problem |
|
|
| remains. |
|
| 4. | Reinstall each device that was removed in |
|
|
| step b one at a time, starting the server |
|
|
| each time, to isolate the failing device. |
|
| 5. | Replace any failing device. |
|
| 6. | (Trained service technician only) Replace |
|
|
| the system board, if the problem remains. |
If the 12V channel D error LED is lit, complete the following steps:
1.Turn the server off and disconnect the power from the server.
2.Remove the microprocessor in socket 1. Note: The server will not
3.Restart the server to see if the problem remains.
4.Reinstall the microprocessor in socket 1 and restart the server.
5.Replace any failing device.
6.(Trained service technician only) Replace the system board, if the problem remains.
(Continued on the next page.)