Installing a SAS controller on the SAS riser card
Important: If you have installed a
To install a SAS controller on the SAS riser card, complete the following steps:
1.Make sure that the server is turned off, all external cables and power cords are disconnected, and the cover has been removed.
2.If you are installing a new or replacement SAS controller, touch the
1 SAS riser card
2 RAID adapter
3.If you are installing a new or replacement SAS controller that uses a battery, complete the following steps:
a.Remove the battery from the SAS controller package or the battery package.
b.Install the battery and connect the battery to the SAS controller as instructed in the documentation that comes with the SAS controller or the battery.
4.If the new SAS controller is a different physical size than the SAS controller you removed, you might have to move the controller retention bracket
5.Turn the SAS controller so that the keys on the bottom edge align correctly with the connector on the SAS riser card in the SAS controller assembly.
6.Firmly press the SAS controller horizontally into the connector on the SAS riser card.
7.
8.Install the SAS riser card and controller assembly (see “Installing the SAS riser card and controller assembly” on page 78).
If you have other optional devices to install or remove, do so now. Otherwise, go to “Completing the installation” on page 100.
Chapter 5. Installing optional devices and replacing customer replaceable units 81