Table 15. EasyLED panel LEDs (continued)

LED

Description

Action

OVER SPEC

The power supplies are

If the OVER SPEC LED on the EasyLED panel

 

using more power than

is lit, or any of the six 12V rail error LEDs (A, B,

 

their maximum rating.

C, D, E, or AUX) on the system board are lit,

 

 

follow the instructions below.

 

 

If the 12V channel A error LED is lit, complete

 

 

the following steps:

 

 

1.

Turn the server off and disconnect the

 

 

 

power from the server.

 

 

2.

Remove the optical drive, fans, hard disk

 

 

 

drives, and hard disk drive backplane.

 

 

3.

Restart the server to see if the problem

 

 

 

remains.

 

 

4.

Reinstall each device that was removed in

 

 

 

step b one at a time, starting the server

 

 

 

each time, to isolate the failing device.

 

 

5.

Replace any failing device.

 

 

6.

(Trained service technician only) Replace

 

 

 

the system board, if the problem remains.

If the 12V channel B error LED is lit, complete the following steps:

1.Turn the server off and disconnect the power from the server.

2.Remove the PCI riser card in connector 1, all DIMMs, and the microprocessor in socket 2.

3.Restart the server to see if the problem remains.

4.Reinstall each device that was removed in step b one at a time, starting the server each time, to isolate the failing device.

5.Replace any failing device.

6.(Trained service technician only) Replace the system board, if the problem remains.

(Continued on the next page)

144ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Installation and User Guide