Table 15. EasyLED panel LEDs (continued)
LED | Description | Action | |
|
|
|
|
PCI | An error has occurred on | 1. | Check the LEDs on the PCI slots to identify |
| a PCI bus or on the | ||
|
| the component that caused the error. | |
| system board. An |
| |
| 2. | Check the | |
| additional LED will be lit | ||
|
| about the error. | |
| next to a failing PCI slot. |
| |
| 3. | If you cannot isolate the failing adapter | |
|
| ||
|
|
| using the LEDs and the information in the |
|
|
| |
|
|
| time from the failing PCI bus; then, restart |
|
|
| the server after each adapter is removed. |
|
| 4. | If the problem remains, replace the following |
|
|
| components, in the order shown, restarting |
|
|
| the server each time: |
|
|
| v PCI riser card |
|
|
| v (Trained service technician only) Replace |
|
|
| the system board, if the problem remains. |
|
|
|
|
SP | The service processor has | 1. | Remove power from the server; then, |
| failed. |
| reconnect the server to power and restart |
|
|
| |
|
|
| the server. |
|
| 2. | Update the IMM firmware. |
|
| 3. | (Trained service technician only) Replace |
|
|
| the system board, if the problem remains. |
|
|
|
|
FAN | A fan has failed, is | 1. | Reseat the fan. |
| operating too slowly, or | ||
| 2. | Replace the failing fan, which is indicated by | |
| has been removed. The | ||
|
| a lit LED next to the fan. | |
| TEMP LED might also be |
| |
|
|
| |
| lit. |
|
|
|
|
|
|
TEMP | The system temperature | 1. | Determine whether a fan has failed. If it has, |
| has exceeded a threshold | ||
|
| replace it. | |
| level. A failing fan can |
| |
| 2. | Make sure that the room temperature is not | |
| cause the TEMP LED to | ||
|
| too high. See “Specifications” on page 10 for | |
| be lit. |
| |
|
| the server temperature information. | |
|
|
| |
|
| 3. | Make sure that the air vents are not |
|
|
| blocked. |
|
|
| |
MEM | A memory error has | Replace the failing DIMM, which is indicated by | |
| occurred. | the lit DIMM latch on the system board (the | |
|
| DIMM LED is underneath the DIMM latch). | |
|
|
| |
NMI | A machine check error | Check the | |
| has occurred or the NMI | the error. | |
| button was pressed. |
|
|
|
|
|
|
CNFG | A hardware configuration | 1. | Check the microprocessors that were just |
| error has occurred. | ||
|
| installed to make sure that they are | |
|
|
| |
|
|
| compatible with each other. |
|
| 2. | (Trained service technician only) Replace |
|
|
| the incompatible microprocessor. |
|
| 3. | Check the |
|
|
| about the error. Replace any components |
|
|
| identified in the error log. |
|
|
|
|